Thermal Class of Magnet Wire: Choosing the Right Rating

By Dien Mac | 11 Nov 2026

Every enamelled winding wire carries a thermal class: 155, 180, 200, 220 or 240 are the common ones. The number is easy to read as a temperature limit for the coil. It is not one. This guide explains what the class does tell you, what it leaves out, and how to choose a class for a real winding.

What the class means

The thermal class describes the finished wire. It is set by the wire's product standard, such as IEC 60317 or NEMA MW 01000 (formerly MW 1000), which names a construction and the class it must meet. The class is backed by thermal endurance testing: IEC 60172 is the test procedure for determining the temperature index of enamelled winding wire. Samples of the wire are aged at elevated temperatures and checked periodically for electrical breakdown, and the results are used to work out the temperature index.

The test is run on the wire alone, without slot liners, varnish or the other materials of a real winding. That is why the result describes the wire, not the winding.

Three different ratings

  • Wire thermal class: What it describes: The finished wire insulation; How it is established: Product standard (IEC 60317, NEMA MW 01000 (formerly MW 1000)), tested to IEC 60172
  • Insulation system class: What it describes: Wire, slot liner, phase insulation and varnish together; How it is established: Evaluation of the whole system under IEC 60085
  • Machine rating: What it describes: The motor or transformer as built; How it is established: The equipment standard, resting on the evaluated insulation system

Most confusion comes from reading one of these as another. A class H motor carries a class H insulation system. That does not mean every wire in it is class 180, and a class 220 wire does not make a winding class 220. For more on the system view, see our articles on insulation classes A to H, thermal class testing under IEC 60085 and wire and insulation in coil winding.

Classes, letters and typical enamels

IEC 60085 gives each thermal class a number and, up to 220, a letter. The ones you meet most on wire are in the table, with the enamel types and NEMA designations from the NEMA and IEC cross-reference and supplier data.

  • 155: IEC 60085 letter: F; Typical insulation: Polyurethane; polyester; Example NEMA types: MW 79-C; MW 5-C
  • 180: IEC 60085 letter: H; Typical insulation: Polyurethane; polyester-imide; Example NEMA types: MW 82-C; MW 30-C
  • 200: IEC 60085 letter: N; Typical insulation: Polyester-imide with polyamide-imide overcoat, on copper; Example NEMA types: MW 35-C; MW 73-C
  • 220: IEC 60085 letter: R; Typical insulation: Polyamide-imide on copper; the dual coat on aluminium; Example NEMA types: MW 81-C; MW 35-A
  • 240: IEC 60085 letter: none; Typical insulation: Aromatic polyimide; Example NEMA types: MW 16-C; MW 20-C

How to choose a class

  1. Find the temperature the coil will see in service, at the hot spot, not the average winding temperature.
  2. Decide the life you need and the duty: continuous, intermittent, or drive-fed.
  3. Check what the complete insulation system has been evaluated for. The wire is one input to that.
  4. Pick the wire class the application needs. A higher class is a higher test requirement, not automatically a better winding.
  5. Check the supplier's datasheet for the exact designation and standard, and confirm with winding trials.

Higher is not always safer. Class 220 wire is not a default upgrade over class 200: the two also differ in construction, and a higher class does not raise a machine's rating by itself. A new rating needs its own system evaluation.

Class and film build are separate

Film build, such as single, heavy, triple or quad in the NEMA scheme, sets the coating thickness, not the thermal class. Specify the class and the build as two separate lines. A thicker film does not raise the class.

Termination and class

Class also affects how you terminate. Solderable polyurethane grades are available at classes 155 and 180. Higher-class enamels such as polyimide are not offered as directly solderable, so terminations are stripped mechanically or chemically. Plan for this early if a design is moving up in class.

Frequently asked questions

What does class 180 mean on magnet wire?

It is a thermal class of 180, the IEC 60085 class H. For the wire, it means the finished wire meets that class under its product standard. It is not an operating limit for the winding.

Is class H the same as class 180?

Yes, class H is the IEC 60085 letter for thermal class 180. A class H motor carries a class H insulation system, which is evaluated as a whole.

Does higher thermal class give a higher motor rating?

Not by itself. A machine rating rests on the evaluated insulation system and the equipment standard, with the wire as one input.

How is magnet wire thermal class tested?

By thermal endurance testing of the finished wire. IEC 60172 is the procedure for determining the temperature index of enamelled winding wire.

Can I solder class 200 or 240 wire?

Those grades are not offered as directly solderable. Direct soldering is a feature of polyurethane grades at classes 155 and 180.

Sources

  • Jingda magnet wire thermal class guide (supplier)
  • IEC 60172 test procedure for temperature index of enamelled winding wire
  • IEC 60085 thermal evaluation and designation
  • NEMA cross reference of NEMA and IEC magnet wire specifications