CWN logo COIL WINDING NEWS Industry news for coil winding professionals
Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

How to Select Enamelled Copper Wire for Coil Winding

By Horst Kunz | 10 Nov 2026

There is no single best enamelled wire. The right one depends on the temperature, the voltage, the winding process and what happens to the coil afterwards. Work through the decisions in order.

Step 1: conductor size and shape

Set the copper size from the current and the space in the coil. Sizes and tolerances come from the standard or the maker's datasheet; see how to read an enamelled copper wire datasheet. If the slot or window is the limit, consider a rectangular conductor; see rectangular vs round magnet wire. For high frequency, see choosing magnet wire for high-frequency applications.

Step 2: thermal class

A wire maker's thermal class sheet explains that thermal class is based on the temperature obtained by extrapolating an Arrhenius plot of life against temperature to a specified time, usually 20,000 hours, with ASTM D 2307 named as the test for film-insulated round wire. The same sheet lists examples by class: polyester at 155 and 180, polyester with an amide-imide topcoat at 200, amide-imide at 220 and polyimide at 240. Pick a class with margin over the hottest spot in the application. See thermal class of magnet wire.

Step 3: insulation type

Match the film to the job. A distributor guide describes polyurethane as tough and flexible, solderable at low temperature, but not compatible with all impregnating varnishes and with a limited shelf life. It describes solderable polyesterimide as adding thermal and solvent resistance and varnish compatibility. A manufacturer's guide lists a nylon overcoat as improving lubricity for ease of winding and a polyamide-imide shield coat for inverter duty and high voltage motors. See polyurethane vs polyesterimide wire and types of magnet wire insulation materials.

Step 4: special features

Step 5: build and standard

Insulation build, such as Grade 1 or Grade 2, changes the overall diameter. Check the maker's table for the increase in dimension due to the insulation. Specify the standard: the NEMA and IEC systems have a published cross reference of equivalent specifications, and NEMA MW 1000 is now MW 01000. Do not mix designations without checking the cross reference.

Step 6: winding and process

  • Machine and tension: a harder or lubricated film suits severe winding stresses.
  • Post-processing: varnish, resin, bonding, soldering. Confirm compatibility with the maker.
  • Storage and shelf life: polyurethane has a limited shelf life, according to the guide above.

Check with the supplier

  1. Standard and designation, with the thermal class.
  2. Insulation grade and overall diameter limits.
  3. Solderability, bonding and varnish compatibility data.
  4. Test reports for your lot: dimensions, elongation, continuity.
  5. Packaging and lead time.

Frequently asked questions

What should I decide first?

Conductor size from current and space, then thermal class, then the insulation type.

How much thermal margin do I need?

Enough to cover the hottest spot in service. Ask your wire maker and apply your own design rules.

Does polyurethane work with every varnish?

No. One guide says it is not compatible with all impregnating varnishes.

Is NEMA MW 1000 still current?

It is now MW 01000, per NEMA's page.

Who confirms the choice?

The wire maker, with test data for your winding process.

Sources

  • Essex: magnet wire thermal class ratings (thermal class definition, insulation types by class, material characteristics)
  • MWS Wire Industries: magnet wire insulation guide (insulation types, NEMA and IEC designations, characteristics and general applications)
  • CMP Controls: copper and aluminium magnet wire guide (choosing magnet wire enamels; enamelling process)
  • NEMA: cross reference of NEMA and IEC magnet wire specifications
  • NEMA: MW 01000 magnet wire standard page (formerly MW 1000)