CWN logo COIL WINDING NEWS Industry news for coil winding professionals
Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

Choosing Magnet Wire for High-Frequency Applications

By Kyoji Takeda | 15 Nov 2026

A wire that works well at 50 Hz can waste a lot of power at 100 kHz. At high frequency, the resistance of a solid conductor rises above its DC value. Choosing the wire is mostly about reducing that rise. For the physics, see skin effect and proximity effect. This article is about selection.

Why the resistance rises

A technical article on litz selection names three frequency effects in a metal conductor: eddy currents from the conductor's own magnetic field, which circulate mainly on its surface; the proximity effect, in which each turn disturbs its neighbours and is disturbed by them; and fringing flux, from time-varying fields such as those at core air gaps. A litz wire supplier describes the result as current migrating to the skin and being pushed away by the field of neighbouring strands, which leaves the core of the conductor useless.

Option 1: solid enamelled wire

For low frequencies, a single round wire is simple and cheap. As frequency rises, its AC resistance climbs. Check the datasheet or a calculation for your frequency before you accept it. Thinner wire helps but has limits, and a very thin single wire may not carry the current.

Option 2: litz wire

Litz wire is a conductor of separately insulated strands, twisted or braided in a pattern. This evens out the flux linkages and reactances of the strands, so the current spreads more uniformly. The AC to DC resistance ratio then tends toward one. The supplier designs each strand to be smaller than the skin depth and transposes the strands through the length of the wire, and says the correct size is set by the frequency.

The same supplier gives a table of recommended strand gauge by frequency. It is one supplier's recommendation and not a standard:

  • 60 Hz to 1 kHz: 28 AWG strands
  • 1 kHz to 10 kHz: 30 AWG
  • 10 kHz to 20 kHz: 33 AWG
  • 20 kHz to 50 kHz: 36 AWG
  • 50 kHz to 100 kHz: 38 AWG
  • 100 kHz to 200 kHz: 40 AWG
  • 200 kHz to 350 kHz: 42 AWG

Higher bands go to 44, 46 and 48 AWG. See also litz wire for high-frequency windings.

Strand insulation

For the strands, the supplier says the commonly used enamels are polyurethane and polyurethane with a nylon topcoat, chosen for low electrical losses and ease of solderability. Solderable strands also change how you terminate the wire; see how to strip enamelled copper wire safely. Litz may also carry an overall served or taped layer.

Option 3: flat conductors and foil

Some suppliers use thin flat conductors or foil for high-current, high-frequency magnetics, because a conductor whose thickness is matched to the skin depth uses its copper more fully. The supplier's own white paper says the benefit depends on layers and geometry and should be checked by simulation or measurement.

Trade-offs

  • Litz lowers AC losses but reduces fill factor. One review gives litz slot fill factors of 0.35 to 0.40.
  • Litz terminations are more complex and expensive, according to the same review.
  • Cost and size rise with strand count.
  • Test the finished winding at the operating frequency.

What to ask the supplier

  • Strand gauge and count for your frequency band.
  • Strand insulation and thermal class.
  • Termination method and how the strands are stripped or fused.
  • AC/DC resistance data or a loss model for your frequency.
  • Tolerance on overall size for winding fit.

Frequently asked questions

Why not just use thinner solid wire?

Thinner wire reduces skin effect but carries less current, so many thin strands in parallel are used. Litz does this with insulated, transposed strands.

How do I choose strand size?

By operating frequency. One supplier recommends 36 AWG strands for 20 to 50 kHz and 40 AWG for 100 to 200 kHz.

What enamel is used on litz strands?

Polyurethane or polyurethane with a nylon topcoat are common, for low loss and solderability, according to one supplier.

Is litz always better?

It lowers AC loss but lowers fill factor and complicates termination. Compare with your design needs.

Do I need to test the winding?

Yes. Check AC resistance or loss at the operating frequency.

Sources

  • New England Wire Technologies: Litz wire design and engineering (skin and proximity effect, litz definition, strand gauge by frequency, strand enamels)
  • EE Power: practical guidelines for litz wire selection, part 1 (three frequency effects)
  • Frontiers in Mechanical Engineering 2026: review of flat-wire windings (litz fill factor and termination cost)
  • ProMagTech: round wire to flat wire technology white paper (supplier; flat conductor and skin depth, verify by simulation)