CWN logo COIL WINDING NEWS Industry news for coil winding professionals
Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

Copper vs Aluminium Magnet Wire: Trade-offs for Windings

By Robert Burns | 12 Nov 2026

Two conductor materials cover almost every magnet wire application: copper and aluminium. Copper is the default. Aluminium is lighter and cheaper by weight, and some motor makers have looked at it to cut material cost. The trade-offs are real, and they affect more than the wire.

Conductivity and size

Annealed copper is the reference at 100 percent IACS. Aluminium is about 61 percent IACS, so for the same resistance it needs a larger cross-section. One manufacturer's white paper gives a rule of thumb: reduce the AWG number by two for equal conductivity, so 20 AWG copper would be replaced by 18 AWG aluminium. That is consistent with the conductivity figure: one AWG step changes the cross-sectional area by about 1.26 times, so two steps is about 1.59 times, close to the 1 divided by 0.61, or 1.64, area ratio. Treat it as an approximation and calculate for your design.

Weight and cost

Aluminium is lighter. The same white paper says that even on an equal conductivity basis, aluminium wire weighs about half as much as copper. Aluminium is also less expensive per kilogram. The catch is volume. An industry technical sheet notes that, because aluminium needs larger conductor cross-sections to compensate for lower conductivity, the volume of the electrical component grows, and the overall material cost may end up higher than with copper because of the bigger housings and laminated cores needed. Metal prices change, so run the numbers with current figures for your own design.

Mechanical behaviour

Aluminium is more brittle than copper, and the same white paper says terminations have to be adjusted for its properties. Datasheets show it too. One manufacturer's data for the same insulated wire lists typical elongation of 38 percent on copper and 25 percent on aluminium, with required minimums of 32 and 15 percent. Springback and cut-through values are given for copper only in that sheet.

Terminations

Termination is the main obstacle. The white paper says the challenge is to make connections to aluminium magnet wire at production speed and reliability equal to copper, and states that this largely rules out soldering and sonic welding for medium and high volume production, which is why it promotes insulation displacement connectors. Another manufacturer says flame welding is not recommended for its aluminium wire. Always check the connection method with your wire supplier.

Standards and availability

In NEMA MW 01000, the MW number ends in -C for copper or -A for aluminium, so the same insulation can be specified on either conductor. See our article on magnet wire standards. Size ranges differ: one supplier lists round copper from 14 to 33 AWG in single build but round aluminium from 14 to 22 AWG. Check availability for the sizes you need.

What to check before switching

  • Redesign for a larger conductor, and check slot or bobbin fill.
  • Confirm the thermal class for the aluminium version of the insulation. One manufacturer rates the same wire Class 200 on copper and Class 220 on aluminium.
  • Choose a termination method qualified for aluminium.
  • Compare total cost, including housings, cores and process changes, not only wire price.
  • Ask the supplier for datasheets for the aluminium grade.

For background on terminology, see magnet wire vs enamelled copper wire and wire insulation in coil winding.

Frequently asked questions

Is aluminium magnet wire as conductive as copper?

No. Aluminium is about 61 percent IACS against 100 percent for annealed copper, so it needs a larger cross-section for the same resistance.

How much larger must aluminium wire be?

As a rule of thumb from one manufacturer, two AWG numbers lower for equal conductivity. Calculate for your own design.

Is aluminium wire cheaper overall?

The wire may be cheaper, but larger cross-sections can mean bigger cores and housings. Compare total cost.

Can I solder aluminium magnet wire?

One manufacturer's paper says soldering is not practical for medium and high volume production of aluminium wire. Ask your supplier about approved methods.

How do NEMA numbers show copper or aluminium?

MW numbers end in -C for copper and -A for aluminium.

Sources

  • TE Connectivity: applying MAG-MATE IDC to aluminum magnet wire, white paper 2011 (supplier; equal conductivity rule, weight, termination)
  • SHWire / Hi-Ecowire: technical sheet on magnet wire and its role in motors (conductivity, volume and housing effects)
  • Essex Solutions: GP/MR-200 datasheet (copper and aluminium elongation, class, availability, flame welding note)
  • NEMA: MW 01000 magnet wire (-C and -A designations)
  • Transnine Electric: copper vs aluminum windings (100 percent IACS reference and about 61 percent for aluminium)