Common Coil Winding Machine Alarms and Troubleshooting

By Will Hunsdorf | 24 Nov 2026

Use the machine manual's alarm list first. The symptoms and causes below come from a manufacturer troubleshooting article for motor winding machines and are general, not specific to your model. Switch off and lock out power before opening any panel, and have electrical work done by a qualified person.

Symptoms and possible causes

  • No power: loose power cable, blown fuse, faulty breaker or power supply failure.
  • Intermittent shutdown: overheating, unstable voltage, weak relay or poor terminal connection.
  • Inaccurate turn count: encoder issue, sensor error, counter malfunction or control signal noise.
  • Servo motor fault, with jerking or alarm codes: drive error, feedback failure, overload or loose encoder wiring.
  • Tension control problem, wire too loose or too tight: tension sensor failure, control board error or worn mechanical parts.
  • Wire break detection error, false alarms or missed breaks: sensor misalignment, contamination or a damaged detection circuit.
  • PLC or HMI communication failure: communication cable fault, software issue or power instability.
  • Emergency stop not working: broken switch, relay failure, wiring fault or safety circuit fault.

A checking order

  1. Read the alarm code and message and write it down.
  2. Check the simple things: power, fuses, breaker, connectors.
  3. Inspect external wiring and connectors. The article names loose terminals, damaged cables and oxidised connectors as common causes, especially near vibration, cable chains, the control box and the spindle.
  4. Check sensors for alignment and dirt.
  5. Check the mechanical side: tension components, guides, rollers.
  6. Test after each change, one change at a time.

Winding problems that are not alarms

Poor layers can come from traverse settings. See coil winding machine traversing systems. Wire breaks may come from tension or wire path problems. See why copper wire breaks during coil winding and wire tensioners for coil winding machines. A wrong turn count points to the encoder or counter. See coil winding machine calibration.

When to stop

Do not bypass a safety circuit or an emergency stop. If the fault involves the safety circuit, the drive or the PLC, contact the machine maker or a qualified technician.

Keep a fault log

Write down the alarm, the time, the product being wound, what you checked and what fixed it. Over a few months the log shows repeat faults, such as one sensor that keeps going out of alignment, and points to the real cause. It also gives the machine maker useful evidence if you need to call for support.

Prevention is simple: keep sensors and encoders clean, check cable chains and terminals on a schedule, and keep the control cabinet free of dust and heat.

Frequently asked questions

What causes a wrong turn count?

An encoder issue, a sensor error, a counter fault or signal noise, per one manufacturer article.

Why does a wire break alarm trigger falsely?

Sensor misalignment, contamination or a damaged detection circuit are listed causes.

What should I check first?

The alarm code, then power and connections.

Can I bypass an emergency stop that fails?

No. Repair it or call a qualified technician.

What causes tension problems?

Tension sensor failure, control board error or worn mechanical parts.

Sources

  • Pugu Electromechanical Technology: motor winding machine, troubleshooting electrical issues (manufacturer article; symptoms and possible causes)
  • Pugu Electromechanical Technology: transformer coil winding machine calibration methods (manufacturer article; calibration sequence and parameters)